MBG914
Conventional fire alarm manual call point that is surface-mounted and used for fire emergency signaling. It is red, features a break-glass design with a protective film on the glass, and is easy to install. Key features include a high-visibility status LED, compatibility with Menvier conventional fire panels, and an included test key for maintenance.
Categories: Fire Alarm System, Smart Security
Description
Description
Conventional fire alarm manual call point that is surface-mounted and used for fire emergency signaling. It is red, features a break-glass design with a protective film on the glass, and is easy to install. Key features include a high-visibility status LED, compatibility with Menvier conventional fire panels, and an included test key for maintenance.
Related products
CF1100
CF2000
EFBW2ZFLEXI
Is a two-zone fire alarm control panel that uniquely combines both two-wire and conventional wiring technologies. This means each zone can be individually configured to operate as either a two-wire or a conventional system, allowing for a flexible mix of both types of devices on the same panel. It features an intuitive interface for straightforward programming and maintenance and meets the EN54 parts 2 and 4 standards.
FL-RL-RD
Conventional xenon sounder beacon for fire and industrial alarm systems, providing both a loud audible alarm and a bright visual flashing light. The "D" in the model number specifically denotes the deep base variant, which is often weatherproof (IP65 rated) for harsher environments. It combines a sounder and a visual beacon into a single unit, reducing installation time and cost.
SG42BK1
Addressable manual station double action • Single/dual action options, Complete with Initiating module
(addressable variants only), Key reset , Corrosion resistant gold plated SPST contacts,High-gloss red enamel finish with raised, white lettering, Class A, style 7 SLC, Quick and simple to install, High quality die cast metal case for lasting, performance, No hard addressing required with initiating unit (ULMCIM-C - plug and play)
Easy to maintain/service.
UCPD-2W
2-Wire, conventional optical smoke detector from Eaton's UL-listed conventional detector range. It's designed for easy installation and maintenance, featuring a discreet, aesthetically pleasing design, a common mounting base, and 360° visibility via a lightpipe LED. This detector is best for detecting slow-burning or smoldering fires that produce large, visible smoke particles.
ULCAH330
Addressable heat detector Rate of rise with fixed heat sensor settings will detect a rapid increase in temperature or temperatures above 135°F, and should be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used, for example where there is a high level of dust, fumes, steam or smoke under normal conditions.
ULMCIM-C
Is a compact, soft-addressed single-channel input module for Eaton intelligent addressable fire alarm systems that monitors non-addressable, dry contact devices like water flow switches or auxiliary fault signals. The "-C" variant is specifically designed for use with pull stations and is identified by the panel as a callpoint. It features an integral short circuit isolator and can be easily installed inside other equipment.