MBG813
Addressable call point break glass oft addressed, Integral short circuit isolator, Single address, Fast fit clip on front cover, High visibility status LED, Wide range of accessories, Heavy duty terminals, Two models available, Internal, Weatherproof.
Categories: Fire Alarm System, Smart Security
Description
Description
Addressable call point break glass oft addressed, Integral short circuit isolator, Single address, Fast fit clip on front cover, High visibility status LED, Wide range of accessories, Heavy duty terminals, Two models available, Internal, Weatherproof.
Related products
CF1100
EFBW2ZFLEXI
Is a two-zone fire alarm control panel that uniquely combines both two-wire and conventional wiring technologies. This means each zone can be individually configured to operate as either a two-wire or a conventional system, allowing for a flexible mix of both types of devices on the same panel. It features an intuitive interface for straightforward programming and maintenance and meets the EN54 parts 2 and 4 standards.
EFBW4ZFLEXI
Is a four-zone fire alarm control panel that uniquely combines both two-wire and conventional wiring technologies. This means each zone can be individually configured to operate as either a two-wire or a conventional system, allowing for a flexible mix of both types of devices on the same panel. It features an intuitive interface for straightforward programming and maintenance and meets the EN54 parts 2 and 4 standards.
FL-RL-RD
Conventional xenon sounder beacon for fire and industrial alarm systems, providing both a loud audible alarm and a bright visual flashing light. The "D" in the model number specifically denotes the deep base variant, which is often weatherproof (IP65 rated) for harsher environments. It combines a sounder and a visual beacon into a single unit, reducing installation time and cost.
FL-RL-RS
Is a conventional xenon sounder beacon, an audible and visual fire alarm device that combines a sounder and a flashing light in a single unit. It is used in fire alarm systems, reduces installation costs by only requiring one installation point, and is available in versions with linked or independent operation for the sounder and beacon. The "-S" typically denotes a shallow base, while "-D" denotes a deep base or weatherproof version
ULCAP320
ULMCIM-C
Is a compact, soft-addressed single-channel input module for Eaton intelligent addressable fire alarm systems that monitors non-addressable, dry contact devices like water flow switches or auxiliary fault signals. The "-C" variant is specifically designed for use with pull stations and is identified by the panel as a callpoint. It features an integral short circuit isolator and can be easily installed inside other equipment.
ULMCOM
Addressable control module a compact, UL-listed micro single-channel output unit for Eaton intelligent addressable fire alarm systems. It provides a solution for switching low-voltage control circuits, such as for HVAC, plant shutdown, or fire doors, and features soft addressing and an integral short-circuit isolator.
