APC-AMC2-4WCF
Door controller Wiegand with CF
card
Four Wiegand interfaces for up to 4 card readers,
network connection to the host system and Compact
Flash memory (2 GB). Host data transfer encrypted.
Categories: Access Control Systems, Smart Security
Description
Description
Door controller Wiegand with CF
card
Four Wiegand interfaces for up to 4 card readers,
network connection to the host system and Compact
Flash memory (2 GB). Host data transfer encrypted.
Related products
EFBW2ZFLEXI
Is a two-zone fire alarm control panel that uniquely combines both two-wire and conventional wiring technologies. This means each zone can be individually configured to operate as either a two-wire or a conventional system, allowing for a flexible mix of both types of devices on the same panel. It features an intuitive interface for straightforward programming and maintenance and meets the EN54 parts 2 and 4 standards.
MMX-4003-12N
MMX-4003-12NXT
SG42BK1
Addressable manual station double action • Single/dual action options, Complete with Initiating module
(addressable variants only), Key reset , Corrosion resistant gold plated SPST contacts,High-gloss red enamel finish with raised, white lettering, Class A, style 7 SLC, Quick and simple to install, High quality die cast metal case for lasting, performance, No hard addressing required with initiating unit (ULMCIM-C - plug and play)
Easy to maintain/service.
UCHR-2W
Is a 2-wire conventional fire detector that combines both rate-of-rise and fixed heat detection. It is designed to respond to a rapid increase in temperature and/or temperatures exceeding a threshold of \(135^{\circ }F\) (\(60^{\circ }C\)), making it suitable for environments where smoke detectors may cause false alarms, such as those with high levels of dust or steam.
ULCAPT340
ULMCIM-C
Is a compact, soft-addressed single-channel input module for Eaton intelligent addressable fire alarm systems that monitors non-addressable, dry contact devices like water flow switches or auxiliary fault signals. The "-C" variant is specifically designed for use with pull stations and is identified by the panel as a callpoint. It features an integral short circuit isolator and can be easily installed inside other equipment.
ULMCOM-S
Is a compact, UL-listed single-channel output unit for Eaton's addressable fire alarm systems, which is identified by the panel as a sounder. It is used to control low-voltage devices by switching them, such as for fire door closures or plant shutdown circuits. The "S" designation signifies its primary use as a sounder, and it features easy, "plug and play" installation with no hard addressing required.