MC16-PAC-ST-2-KIT
three-door access control kit for the RACS 5 v2 ST system.
The kit comprises a metal enclosure with a power supply,
a door expander and a network access controller. MC16
PAC-ST-3-KIT enables the implementation of read-in/
read-out access control for two doors using RS485 (MCT
series readers), RACS CLK/DTA (PRT series readers) or
Wiegand readers.
Categories: Access Control Systems, Smart Security
Description
Description
three-door access control kit for the RACS 5 v2 ST system.
The kit comprises a metal enclosure with a power supply,
a door expander and a network access controller. MC16
PAC-ST-3-KIT enables the implementation of read-in/
read-out access control for two doors using RS485 (MCT
series readers), RACS CLK/DTA (PRT series readers) or
Wiegand readers.
Related products
CF2000
EFBW4ZFLEXI
Is a four-zone fire alarm control panel that uniquely combines both two-wire and conventional wiring technologies. This means each zone can be individually configured to operate as either a two-wire or a conventional system, allowing for a flexible mix of both types of devices on the same panel. It features an intuitive interface for straightforward programming and maintenance and meets the EN54 parts 2 and 4 standards.
MBG914
Conventional fire alarm manual call point that is surface-mounted and used for fire emergency signaling. It is red, features a break-glass design with a protective film on the glass, and is easy to install. Key features include a high-visibility status LED, compatibility with Menvier conventional fire panels, and an included test key for maintenance.
MMX-4003-12NXT
SG42BK1
Addressable manual station double action • Single/dual action options, Complete with Initiating module
(addressable variants only), Key reset , Corrosion resistant gold plated SPST contacts,High-gloss red enamel finish with raised, white lettering, Class A, style 7 SLC, Quick and simple to install, High quality die cast metal case for lasting, performance, No hard addressing required with initiating unit (ULMCIM-C - plug and play)
Easy to maintain/service.
ULCAH330
Addressable heat detector Rate of rise with fixed heat sensor settings will detect a rapid increase in temperature or temperatures above 135°F, and should be used in environments where the ambient conditions might cause false alarms if smoke detection were to be used, for example where there is a high level of dust, fumes, steam or smoke under normal conditions.
ULCF30004GPNC
ULMCOM-S
Is a compact, UL-listed single-channel output unit for Eaton's addressable fire alarm systems, which is identified by the panel as a sounder. It is used to control low-voltage devices by switching them, such as for fire door closures or plant shutdown circuits. The "S" designation signifies its primary use as a sounder, and it features easy, "plug and play" installation with no hard addressing required.
