946
IP Overdoor Light Plus 946
Over Door Light provides an instant visual aid
to nursing staff for alerts and calls from patient rooms.
The
Category: Nurse Call System
Description
Description
IP Overdoor Light Plus 946
Over Door Light provides an instant visual aid
to nursing staff for alerts and calls from patient rooms.
The
Related products
NC806CS
Overdoor Light c/w Sounder
Provides audible and visual indication of 800 Series Alarm calls outside bedrooms, WCs and any other area fitted
with an 800 Series calling device.
Indicates Standard calls via a constant tone/constant red light and Emergency calls via a pulsing tone/pulsing red
light.
Dual red LEDs and triangular diffuser make it highly visible from a distance.
Mounts on a standard UK 25mm single gang flush or surface back box.
Can also be used as an 'area indicator' at corridor junctions, staff workstations, etc.
Finished in tough, durable ABS plastic.
Also available as part of the NC951 Accessible Toilet Alarm kit.
Stainless steel version also available.
NC807C
Ceiling/Wall Pull Unit
Can be used to generate a standard call on an 800 Series Conventional Call System.
Ceiling or wall mountable.
Typically wired to an 800 Series Call Point or Reset Point so that its calls can be cancelled.
Supplied with 3m of red nylon pull cord and two red open-sided triangular bangles for ease of use by the infirm.
Red confidence LED and diffuser emits a bright red glow over a wide area to reassure the user that a call has been made.
Surface mountable.
Base fits 16mm conduit and BESA centres.
NC920S
20 Zone Call Controller c/w 300mA PSU (Surface Version)
20 Zone Call Controller c/w 300mA PSU (Surface Version)
Compatible with C-TEC’s entire range of 800 Series field devices.
Housed in an attractive surface mounting plastic enclosure measuring just 214mm x 178mm
Two call levels – standard (constant tone) and emergency (intermittent tone).
Optional mute and call accept/reset buttons.
‘Call Accept’ functionality allows staff to send an intermittent call acknowledgment signal to calling zones to confirm help is on the way (dependent on wiring and field devices used).
Includes a 12V 300mA PSU and 2 volt-free relay contacts which activate on a standard or emergency call.
NC944
Four Zone Call Controller (requires NC930 12V 250mA PSU)
An attractively-designed four zone call controller c/w mute and reset buttons.
Fully compatible with C-TEC's entire range of 800 Series Call System components.
Capable of indicating standard (constant tone) and emergency (intermittent tone) calls.
Requires a separate NC930 12V 250mA PSU.
Includes four zonal alarm LEDs, RESET and MUTE buttons.
Two open collector outputs (Emergency and Aux Out).
Up to two NC944s can be connected to one NC930 PSU to create a mini-call system of up to 8 zones.
Mounts on a standard 25mm UK double gang back box.
QT-603
Quantec Network Splitter
An essential wiring/installation aid for C-TEC’s Quantec Addressable Call System.
Helps protect against open and short circuit faults and reduces the risk of volt drop.
Includes one input and one output connection for Quantec’s ‘Spine’ wiring (typically 1.5-2.5mm T&E) and six fused 400mA ‘limb’ connections for the wiring of individual circuits containing Quantec’s field devices (typically 4 core stranded security cable).
At least one QT603 is required per Quantec system (the more you use, the easier it will be to program and fault-find).
Install one QT603 per corridor junction (locate at the end of the corridor nearest to the Quantec Controller). If the corridor is longer than 50m, install the splitter in the centre of the corridor to reduce wiring runs.
Mounts on a standard 25mm UK double gang back box.
‘Power’ and ‘Fault’ indicators.
Max. 60 addressable devices per QT603.
QT606
Overdoor Light
Provides visual indication of calls made from a Quantec call point outside bedrooms, WCs, etc.
Flash and colour sequence changes/intensifies to reflect the urgency of the incoming call.
Dual red and green LEDs and triangular diffuser make it highly visible from a distance.
Mounts on a standard UK 25mm single gang flush or surface back box.
Finished in tough, durable ABS plastic.
Overdoor lights with sounders and addressable overdoor lights and sounders (to provide area indication at corridor junctions etc.) are also available.
QT607
Ceiling/Wall Pull Unit
Can be used to generate a Standard or Ensuite call on a Quantec Addressable Call System.
Ceiling or wall mountable.
Typically wired to a Quantec Addressable Call Point or Quantec Accessible Toilet Reset Point.
Supplied with 3m of red nylon pull cord and two red open-sided triangular bangles for ease of use by the infirm.
Red confidence LED and diffuser emits a bright red glow over a wide area to reassure the user that a call has been made.
Surface mountable
QT608C
Quantec Corridor Display
A 16 character x 2 line display used to indicate incoming calls in corridors, staff rooms, nursing stations, etc.
Includes an onboard sounder and buttons to accept, scroll through and manually divert calls.
Shows call type, call location and (depending on the device used to make the call) the User ID or name of the person calling.
Highest priority calls are shown first with a message saying how many calls are waiting.
Flash and sounder rates intensify to reflect the urgency of incoming calls.
Adjustable contrast and volume controls.
External sounder connection.